{"id":7970,"date":"2024-11-01T19:39:12","date_gmt":"2024-11-01T17:39:12","guid":{"rendered":"https:\/\/www.sigalou-domotique.fr\/?p=7970"},"modified":"2026-01-01T15:03:35","modified_gmt":"2026-01-01T13:03:35","slug":"je-teste-le-module-lixee-tic-vers-zigbee","status":"publish","type":"post","link":"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee","title":{"rendered":"I am testing the LIXEE TIC module to Zigbee (Zlinky_TIC)"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<label for=\"ez-toc-cssicon-toggle-item-6ada6aff0f776\" class=\"ez-toc-cssicon-toggle-label\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/label><input type=\"checkbox\"  id=\"ez-toc-cssicon-toggle-item-6ada6aff0f776\"  aria-label=\"Toggle\" \/><nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Ou_acheter_cet_equipement\" >Where to buy this equipment?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Jouvre_la_boite_et_verifie_le_modele_recu\" >I open the box and check the received model<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Je_vais_connecter_le_module\" >I will connect the module<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Je_verifie_letat_du_module_grace_a_la_LED\" >I check the status of the module using the LED<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Je_tente_une_integration_Zigbee2MQTT\" >I'm trying a Zigbee2MQTT integration<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Je_teste_le_capteur_dans_Home_Assistant\" >I test the sensor in Home Assistant<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Signification_de_chaque_donnee\" >Meaning of each data<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Je_desactive_toutes_les_entites_qui_ne_me_sont_pas_utiles\" >I disable all entities that are not useful to me<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Je_mets_a_jour_le_module_Zlinky_TIC\" >I am updating the module Zlinky_TIC<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Je_regarde_la_page_parametres_dans_Zigbee2MQTT\" >I look at the settings page in Zigbee2MQTT<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Archive_Jutilise_un_template_pour_HCHP\" >[Archive] I use a template for HC\/HP<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Changement_de_mode_Linky\" >Change of mode Linky<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Bascule_du_mode_Historique_au_mode_Standard\" >Switches from History Mode to Standard Mode<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Donnees_du_mode_Standard\" >Standard Mode Data<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Donnees_Home_Assistant_sur_mode_Standard\" >Data Home Assistant on Standard Mode<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Tentative_de_comprehension_des_changements_detats_HCHP\" >Attempt to understand changes in HC\/HP states<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Jajoute_un_Template_pour_avoir_HCHP\" >I add a template to have HC\/HP<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Comprendre_les_5_lignes_Energie\" >Understanding the 5 Energy Lines<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Jajoute_les_informations_de_conso_dans_Energy\" >I add conso information in Energy<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Donnees_que_je_conserve_finalement\" >Data that I finally keep<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Precision_de_la_configuration_du_module_dans_Zigbee2MQTT\" >Accuracy of module configuration in Zigbee2MQTT<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Conclusion\" >Conclusion<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/www.sigalou-domotique.fr\/en\/je-teste-le-module-lixee-tic-vers-zigbee\/#Bibliographie_ou_references\" >Bibliography or references<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Ou_acheter_cet_equipement\"><\/span>Where to buy this equipment?<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>Here is the link to his page dedicated to the <a href=\"https:\/\/www.sigalou-domotique.fr\/en\/product\/zlinkytic\/\" target=\"_blank\" rel=\"noopener\">ZlinkyTIC<\/a>. I referenced the sellers and prices.<\/p>\r\n<p><!--more--><\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Jouvre_la_boite_et_verifie_le_modele_recu\"><\/span>I open the box and check the received model<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7974\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184020.jpg\" alt=\"\" width=\"562\" height=\"484\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184020.jpg 1914w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184020-600x517.jpg 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184020-300x259.jpg 300w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184020-1024x883.jpg 1024w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184020-768x662.jpg 768w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184020-1536x1324.jpg 1536w\" sizes=\"auto, (max-width: 562px) 100vw, 562px\" \/><!--more--><\/p>\r\n<p>There are obviously two versions, one with internal antenna and one with external antenna.<br \/>The second is probably provided for when disturbances are generated and may need to move the antenna away from the housing.<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7975\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184001.jpg\" alt=\"\" width=\"562\" height=\"472\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184001.jpg 2478w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184001-600x504.jpg 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184001-300x252.jpg 300w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184001-1024x860.jpg 1024w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184001-768x645.jpg 768w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184001-1536x1291.jpg 1536w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184001-2048x1721.jpg 2048w\" sizes=\"auto, (max-width: 562px) 100vw, 562px\" \/><\/p>\r\n<p>The module is very simple, 3 rigid connectors, no instructions for use, I think it is a pretty good sign, it must be very simple.<\/p>\r\n<p>On the back, we see a diagram that shows or puts the module in the Linky.<\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Je_vais_connecter_le_module\"><\/span>I will connect the module<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>I look at how the terminal blocks of the Linky and the module are marked, it is impossible not to understand:<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7976\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184512.jpg\" alt=\"\" width=\"419\" height=\"426\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184512.jpg 1452w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184512-600x610.jpg 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184512-295x300.jpg 295w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184512-1007x1024.jpg 1007w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184512-768x781.jpg 768w\" sizes=\"auto, (max-width: 419px) 100vw, 419px\" \/><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-8019\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/Installation_ZLinky_v2-1.png\" alt=\"\" width=\"281\" height=\"434\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/Installation_ZLinky_v2-1.png 361w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/Installation_ZLinky_v2-1-194x300.png 194w\" sizes=\"auto, (max-width: 281px) 100vw, 281px\" \/><\/p>\r\n<p>I put ZigbeetoMQTT in pairing mode and connect the case, just press the black button to release the connect and slide the pins underneath.\u00a0<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7977\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184736-scaled.jpg\" alt=\"\" width=\"415\" height=\"553\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184736-scaled.jpg 1920w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184736-scaled-600x800.jpg 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184736-225x300.jpg 225w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184736-768x1024.jpg 768w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184736-1152x1536.jpg 1152w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/20241101_184736-1536x2048.jpg 1536w\" sizes=\"auto, (max-width: 415px) 100vw, 415px\" \/><\/p>\r\n<p>The blue LED flashes, the pairing is underway, I go back to Zigbee2MQTT to see the result.<\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Je_verifie_letat_du_module_grace_a_la_LED\"><\/span>I check the status of the module using the LED<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>The LED can have three states, if it is not good at this stage, there is no need to go further.<\/p>\r\n<ul>\r\n<li>The LED flashes quickly several times = <a href=\"https:\/\/www.sigalou-domotique.fr\/en\/product\/zlinkytic\/\" target=\"_blank\" rel=\"noopener\">ZlinkyTIC<\/a> is in pairing-waiting mode.\u00a0<\/li>\r\n<\/ul>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8109\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/ZLinky_v2_pair.gif\" alt=\"\" width=\"288\" height=\"404\" \/><\/p>\r\n<ul>\r\n<li>LED flashes several times slowly = <a href=\"https:\/\/www.sigalou-domotique.fr\/en\/product\/zlinkytic\/\" target=\"_blank\" rel=\"noopener\">ZlinkyTIC<\/a> encounters errors when acquiring Linky data. \ud83d\ude25<\/li>\r\n<\/ul>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8110\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/ZLinky_v2_blink_off.gif\" alt=\"\" width=\"288\" height=\"404\" \/><\/p>\r\n<ul>\r\n<li>The LED flashes once every 3 seconds = The <a href=\"https:\/\/www.sigalou-domotique.fr\/en\/product\/zlinkytic\/\" target=\"_blank\" rel=\"noopener\">ZlinkyTIC<\/a> works properly. The device correctly decodes the Linky \ud83d\ude0a<\/li>\r\n<\/ul>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8111\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/ZLinky_v2_Blink_ok.gif\" alt=\"\" width=\"288\" height=\"404\" \/><\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Je_tente_une_integration_Zigbee2MQTT\"><\/span>I'm trying a Zigbee2MQTT integration<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>The integration worked perfectly at first.<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7978\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky01.png\" alt=\"\" width=\"1050\" height=\"69\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky01.png 1050w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky01-600x39.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky01-300x20.png 300w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky01-1024x67.png 1024w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky01-768x50.png 768w\" sizes=\"auto, (max-width: 1050px) 100vw, 1050px\" \/><\/p>\r\n<p>The module is detected in \"ZLinky_TIC\"<\/p>\r\n<p>The detected version does not differentiate between V1 and V2, it does not matter<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7979\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky02.png\" alt=\"\" width=\"657\" height=\"607\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky02.png 767w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky02-600x554.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky02-300x277.png 300w\" sizes=\"auto, (max-width: 657px) 100vw, 657px\" \/><\/p>\r\n<p>I will look at the values, everything is there, magical, in a few seconds.<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7980\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky03.png\" alt=\"\" width=\"657\" height=\"832\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky03.png 657w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky03-600x760.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky03-237x300.png 237w\" sizes=\"auto, (max-width: 657px) 100vw, 657px\" \/><\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Je_teste_le_capteur_dans_Home_Assistant\"><\/span><span id=\"Je_teste_la_sirene_dans_Home_Assistant\" class=\"ez-toc-section\"><\/span>I test the sensor in Home Assistant<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>I give it an understandable name: Linky in Zigbee2MQTT then I'll look it up in HA<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7981\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky04.png\" alt=\"\" width=\"585\" height=\"331\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky04.png 585w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky04-300x170.png 300w\" sizes=\"auto, (max-width: 585px) 100vw, 585px\" \/><\/p>\r\n<p>And that's it, all the data is present in Home Assistant.<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7982\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky05.png\" alt=\"\" width=\"669\" height=\"814\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky05.png 669w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky05-600x730.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky05-247x300.png 247w\" sizes=\"auto, (max-width: 669px) 100vw, 669px\" \/><\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Signification_de_chaque_donnee\"><\/span>Meaning of each data<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>A small painting is much more telling. For the three-phase, the result will be different.<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7985\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky06.png\" alt=\"\" width=\"594\" height=\"254\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky06.png 594w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky06-300x128.png 300w\" sizes=\"auto, (max-width: 594px) 100vw, 594px\" \/><\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Je_desactive_toutes_les_entites_qui_ne_me_sont_pas_utiles\"><\/span>I disable all entities that are not useful to me<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>Here are the entities of the Linky device:<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7991\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky09.png\" alt=\"\" width=\"675\" height=\"595\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky09.png 675w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky09-600x529.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky09-300x264.png 300w\" sizes=\"auto, (max-width: 675px) 100vw, 675px\" \/><\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Je_mets_a_jour_le_module_Zlinky_TIC\"><\/span>I am updating the module Zlinky_TIC<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7994\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky07.png\" alt=\"\" width=\"597\" height=\"300\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky07.png 597w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky07-300x151.png 300w\" sizes=\"auto, (max-width: 597px) 100vw, 597px\" \/><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7995\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky08.png\" alt=\"\" width=\"597\" height=\"300\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky08.png 597w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky08-300x151.png 300w\" sizes=\"auto, (max-width: 597px) 100vw, 597px\" \/><\/p>\r\n<p>I launched it via Home Assistant, but it can be launched from Zigbee2MQTt, in both cases, we can see that the update is in progress in Zigbee2MQTT as well:<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7996\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky10.png\" alt=\"\" width=\"134\" height=\"66\" \/><\/p>\r\n<p>Be careful, the update is very long, you have to let \u2026 run<\/p>\r\n<p>In the end, I am not sure why this update started, as version 14 was already installed before the update. It does not matter, everything went well and the update flag went back to off.<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8002\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky12.png\" alt=\"\" width=\"325\" height=\"107\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky12.png 325w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky12-300x99.png 300w\" sizes=\"auto, (max-width: 325px) 100vw, 325px\" \/><\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Je_regarde_la_page_parametres_dans_Zigbee2MQTT\"><\/span>I look at the settings page in Zigbee2MQTT<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7999\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky11.png\" alt=\"\" width=\"906\" height=\"729\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky11.png 906w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky11-600x483.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky11-300x241.png 300w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky11-768x618.png 768w\" sizes=\"auto, (max-width: 906px) 100vw, 906px\" \/><\/p>\r\n<p>I found this page, there are no parameters, I do not know if it is useful. When in doubt, I configure.<br \/>Note, Update, small error, do not set KWh to 0 but to 3 because those are K.<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8003\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky13.png\" alt=\"\" width=\"923\" height=\"721\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky13.png 923w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky13-600x469.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky13-300x234.png 300w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky13-768x600.png 768w\" sizes=\"auto, (max-width: 923px) 100vw, 923px\" \/><\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Archive_Jutilise_un_template_pour_HCHP\"><\/span>[Archive] I use a template for HC\/HP<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>I give here the template that I had made a historical mode to retrieve the HC or HP info according to the schedules.<br \/>Indeed, before the installation of this new Zigbee module, I used a USB ICT module.<\/p>\r\n<p>This module also provided me with an HC.. or an HP.. value in the sensor.linky _active _register _tier _delivered (PTEC) variable.<\/p>\r\n<p>To do this, I use a template entity, in the template.yaml file, I add:<\/p>\r\n<pre class=\"EnlighterJSRAW\" data-enlighter-language=\"yaml\">- sensor: - name: Single current _id tariff period: sensor.period _tarifaire _en _cours state: &gt;- {% if is_state(\"sensor.linky _active _register _tier _delivered\", \"HP..\") %} HP {% else %} HC {% endif %}<\/pre>\r\n<h2><span class=\"ez-toc-section\" id=\"Changement_de_mode_Linky\"><\/span>Change of mode Linky<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>There are two modes, History Mode and Standard Mode.<\/p>\r\n<p>I had ICT equipment that was not compatible with Standard mode, so I never changed.<\/p>\r\n<p>Apart from this new module, it also operates in Standard mode according to its documentation. The standard mode is much more complete.<\/p>\r\n<p>I am therefore sending a message to EDF to change the mode:<\/p>\r\n<ul>\r\n<li><a href=\"https:\/\/particulier.edf.fr\/fr\/accueil\/espace-client\/contact\/demande\/formulaire\/decret-conso.html#\/selection-droit-exerce\" target=\"_blank\" rel=\"noopener\">https:\/\/particulier.edf.fr\/fr\/accueil\/espace-client\/contact\/demande\/formulaire\/decret-conso.html#\/selection-droit-exerce<\/a><\/li>\r\n<\/ul>\r\n<p>&nbsp;<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8068\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky14-1.png\" alt=\"\" width=\"1055\" height=\"425\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky14-1.png 1055w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky14-1-600x242.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky14-1-300x121.png 300w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky14-1-1024x413.png 1024w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky14-1-768x309.png 768w\" sizes=\"auto, (max-width: 1055px) 100vw, 1055px\" \/><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8070\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky15-1.png\" alt=\"\" width=\"1152\" height=\"226\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky15-1.png 1152w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky15-1-600x118.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky15-1-300x59.png 300w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky15-1-1024x201.png 1024w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky15-1-768x151.png 768w\" sizes=\"auto, (max-width: 1152px) 100vw, 1152px\" \/><\/p>\r\n<ul>\r\n<li>Online application made via the form on 03 November<\/li>\r\n<li>Reply on 04 November<\/li>\r\n<li>Switches to 05 November<\/li>\r\n<\/ul>\r\n<p>Nothing to say, hat EDF!!<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8075\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky16.png\" alt=\"\" width=\"632\" height=\"506\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky16.png 632w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky16-600x480.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky16-300x240.png 300w\" sizes=\"auto, (max-width: 632px) 100vw, 632px\" \/><\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Bascule_du_mode_Historique_au_mode_Standard\"><\/span>Switches from History Mode to Standard Mode<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>I must admit I skated a little on this switch to Zigbee and Home Assistant.<\/p>\r\n<p>I tried to change the mode, to re-pair the \u2026 module The information did not go back, I spent a while there.<\/p>\r\n<p>Finally, I closed everything, let it go for one night and took it back the next day, everything worked!<\/p>\r\n<p>So you don't have to be in a hurry, there have to be \u2026 refresh cycles in short, it works, here are the screens.<\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Donnees_du_mode_Standard\"><\/span>Standard Mode Data<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\n<table id=\"tablepress-9\" class=\"tablepress tablepress-id-9\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">ICT control<\/th><th class=\"column-2\">designation<\/th><th class=\"column-3\">unit<\/th><th class=\"column-4\">Default value<\/th><th class=\"column-5\">How<\/th><th class=\"column-6\">data type<\/th><th class=\"column-7\">size max<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">ADSC<\/td><td class=\"column-2\">Secondary address of the Counter<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">NULL<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">String<\/td><td class=\"column-7\">12 because<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">NGTF<\/td><td class=\"column-2\">Name of the supplier tariff schedule<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">&#8211;<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">String<\/td><td class=\"column-7\">16 because<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">LTARF<\/td><td class=\"column-2\">Supplier tariff wording in progress<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">&#8211;<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">String<\/td><td class=\"column-7\">16 because<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">NTARF<\/td><td class=\"column-2\">Current tariff index number<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">&#8211;<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint8<\/td><td class=\"column-7\">2 car<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">VTIC<\/td><td class=\"column-2\">ICT version<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">&#8211;<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">2 car<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">DATE<\/td><td class=\"column-2\">Current date and time<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">EX: E211022162000<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">String<\/td><td class=\"column-7\">10 cars<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">EAST<\/td><td class=\"column-2\">Total active energy extracted<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint48<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">EASF01<\/td><td class=\"column-2\">Active energy extracted Supplier, index 01<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint48<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">EASF02<\/td><td class=\"column-2\">Active energy extracted Supplier, index 02<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint48<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">EASF03<\/td><td class=\"column-2\">Active energy extracted Supplier, index 03<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint48<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">EASF04<\/td><td class=\"column-2\">Active energy extracted Supplier, index 04<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint48<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">EASF05<\/td><td class=\"column-2\">Active energy extracted Supplier, index 05<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint48<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">EASF06<\/td><td class=\"column-2\">Active energy extracted Supplier, index 06<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint48<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">EASF07<\/td><td class=\"column-2\">Active energy extracted Supplier, index 07<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint48<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">EASF08<\/td><td class=\"column-2\">Active energy extracted Supplier, index 08<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint48<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">EASF09<\/td><td class=\"column-2\">Active energy extracted Supplier, index 09<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint48<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">EASF10<\/td><td class=\"column-2\">Active energy extracted Supplier, index10<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint48<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">EASD01<\/td><td class=\"column-2\">Active energy extracted Distributor, index 01<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint32<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">EASD02<\/td><td class=\"column-2\">Active energy extracted Distributor, index 02<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint32<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">EASD03<\/td><td class=\"column-2\">Active energy extracted Distributor, index 03<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint32<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">EASD04<\/td><td class=\"column-2\">Active energy extracted Distributor, index 04<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint32<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">EAIT<\/td><td class=\"column-2\">Total injected active energy<\/td><td class=\"column-3\">Wh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Production<\/td><td class=\"column-6\">Uint48<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">ERQ1<\/td><td class=\"column-2\">Total Q1 reactive energy<\/td><td class=\"column-3\">VArh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Production<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">ERQ2<\/td><td class=\"column-2\">Total Q2 reactive energy<\/td><td class=\"column-3\">VArh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Production<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">ERQ3<\/td><td class=\"column-2\">Total Q3 reactive energy<\/td><td class=\"column-3\">VArh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Production<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">ERQ4<\/td><td class=\"column-2\">Total Q4 reactive energy<\/td><td class=\"column-3\">VArh<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Production<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">9 because<\/td>\n<\/tr>\n<tr class=\"row-28\">\n\t<td class=\"column-1\">IRMS1<\/td><td class=\"column-2\">Effective current, phase 1<\/td><td class=\"column-3\">A<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">single\/three-phase<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">3 cars<\/td>\n<\/tr>\n<tr class=\"row-29\">\n\t<td class=\"column-1\">IRMS2<\/td><td class=\"column-2\">Effective current, phase 2<\/td><td class=\"column-3\">A<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">3 cars<\/td>\n<\/tr>\n<tr class=\"row-30\">\n\t<td class=\"column-1\">IRMS3<\/td><td class=\"column-2\">Effective current, phase 3<\/td><td class=\"column-3\">A<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">3 cars<\/td>\n<\/tr>\n<tr class=\"row-31\">\n\t<td class=\"column-1\">URMS1<\/td><td class=\"column-2\">Effective Voltage, Phase 1<\/td><td class=\"column-3\">V<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">single\/three-phase<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">3 cars<\/td>\n<\/tr>\n<tr class=\"row-32\">\n\t<td class=\"column-1\">URMS2<\/td><td class=\"column-2\">Effective Voltage, Phase 2<\/td><td class=\"column-3\">V<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">3 cars<\/td>\n<\/tr>\n<tr class=\"row-33\">\n\t<td class=\"column-1\">URMS3<\/td><td class=\"column-2\">Effective voltage, phase 3<\/td><td class=\"column-3\">V<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">3 cars<\/td>\n<\/tr>\n<tr class=\"row-34\">\n\t<td class=\"column-1\">PREF<\/td><td class=\"column-2\">Power reference app. (PREF)<\/td><td class=\"column-3\">kVA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">2 car<\/td>\n<\/tr>\n<tr class=\"row-35\">\n\t<td class=\"column-1\">STGE<\/td><td class=\"column-2\">Register of Statutes<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">String<\/td><td class=\"column-7\">8 because<\/td>\n<\/tr>\n<tr class=\"row-36\">\n\t<td class=\"column-1\">PCOUP<\/td><td class=\"column-2\">Power cut-off app. (PCOUP)<\/td><td class=\"column-3\">kVA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint8<\/td><td class=\"column-7\">2 car<\/td>\n<\/tr>\n<tr class=\"row-37\">\n\t<td class=\"column-1\">SINSTI<\/td><td class=\"column-2\">Power app. Instant injected<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Production<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-38\">\n\t<td class=\"column-1\">SMAXIN<\/td><td class=\"column-2\">Max. app power injected n<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Production<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-39\">\n\t<td class=\"column-1\">SMAXIN-1<\/td><td class=\"column-2\">Max. injected app power n-1<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Production<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-40\">\n\t<td class=\"column-1\">CCASN<\/td><td class=\"column-2\">Point n of the drawn active load curve<\/td><td class=\"column-3\">W<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-41\">\n\t<td class=\"column-1\">CCASN-1<\/td><td class=\"column-2\">Point n-1 of the drawn active load curve<\/td><td class=\"column-3\">W<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-42\">\n\t<td class=\"column-1\">CCAIN<\/td><td class=\"column-2\">Point n of the injected active load curve<\/td><td class=\"column-3\">W<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Production<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-43\">\n\t<td class=\"column-1\">CCAIN-1<\/td><td class=\"column-2\">Point n-1 of the injected active load curve<\/td><td class=\"column-3\">W<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Production<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-44\">\n\t<td class=\"column-1\">UMOY1<\/td><td class=\"column-2\">Moy voltage. ph. 1<\/td><td class=\"column-3\">V<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Mono\/three-phase<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">3 cars<\/td>\n<\/tr>\n<tr class=\"row-45\">\n\t<td class=\"column-1\">UMOY2<\/td><td class=\"column-2\">Moy voltage. ph. 2<\/td><td class=\"column-3\">V<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">3 cars<\/td>\n<\/tr>\n<tr class=\"row-46\">\n\t<td class=\"column-1\">UMOY3<\/td><td class=\"column-2\">Moy voltage. ph. 3<\/td><td class=\"column-3\">V<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">3 cars<\/td>\n<\/tr>\n<tr class=\"row-47\">\n\t<td class=\"column-1\">SINSTS<\/td><td class=\"column-2\">Power app. Snapshot extracted<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">(Mono\/Triphase since v10)<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-48\">\n\t<td class=\"column-1\">SINSTS<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-49\">\n\t<td class=\"column-1\">SINSTS1<\/td><td class=\"column-2\">Power app. Snapshot extracted ph.1<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-50\">\n\t<td class=\"column-1\">SINSTS2<\/td><td class=\"column-2\">Power app. Instant extracted ph. 2<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-51\">\n\t<td class=\"column-1\">SINSTS3<\/td><td class=\"column-2\">Power app. Instant extracted ph. 3<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-52\">\n\t<td class=\"column-1\">SMAXN<\/td><td class=\"column-2\">Power app. max. drawn n<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">(Mono \/ Triphas\u00e9 since v10)<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-53\">\n\t<td class=\"column-1\">SMAXN<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-54\">\n\t<td class=\"column-1\">SMAXN1<\/td><td class=\"column-2\">Power app. max. drawn n ph.1<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-55\">\n\t<td class=\"column-1\">SMAXN2<\/td><td class=\"column-2\">Power app. max. drawn n ph. 2<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-56\">\n\t<td class=\"column-1\">SMAXN3<\/td><td class=\"column-2\">Power app. max. drawn n ph. 3<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">int16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-57\">\n\t<td class=\"column-1\">SMAXN-1<\/td><td class=\"column-2\">App. max. output power n-1<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">(Mono \/ Triphas\u00e9 since v10)<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-58\">\n\t<td class=\"column-1\">SMAXN-1<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-59\">\n\t<td class=\"column-1\">SMAXN1-1<\/td><td class=\"column-2\">App. max. output power n-1 ph.1<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-60\">\n\t<td class=\"column-1\">SMAXN2-1<\/td><td class=\"column-2\">App. max. output power n-1 ph.2<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-61\">\n\t<td class=\"column-1\">SMAXN3-1<\/td><td class=\"column-2\">App. max. output power n-1 ph.3<\/td><td class=\"column-3\">VA<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\">Three-phased<\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">5 because<\/td>\n<\/tr>\n<tr class=\"row-62\">\n\t<td class=\"column-1\">MSG1<\/td><td class=\"column-2\">Short message<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">String<\/td><td class=\"column-7\">32 because<\/td>\n<\/tr>\n<tr class=\"row-63\">\n\t<td class=\"column-1\">MSG2<\/td><td class=\"column-2\">Ultra-short message<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">String<\/td><td class=\"column-7\">16 because<\/td>\n<\/tr>\n<tr class=\"row-64\">\n\t<td class=\"column-1\">PRM<\/td><td class=\"column-2\">PRM (Identifier)<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">String<\/td><td class=\"column-7\">14 because<\/td>\n<\/tr>\n<tr class=\"row-65\">\n\t<td class=\"column-1\">DPM1<\/td><td class=\"column-2\">Start Point Mobile 1<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint8<\/td><td class=\"column-7\">2 car<\/td>\n<\/tr>\n<tr class=\"row-66\">\n\t<td class=\"column-1\">FPM1<\/td><td class=\"column-2\">End Point Mobile 1<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint8<\/td><td class=\"column-7\">2 car<\/td>\n<\/tr>\n<tr class=\"row-67\">\n\t<td class=\"column-1\">DPM2<\/td><td class=\"column-2\">Start Point Mobile 2<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint8<\/td><td class=\"column-7\">2 car<\/td>\n<\/tr>\n<tr class=\"row-68\">\n\t<td class=\"column-1\">FPM2<\/td><td class=\"column-2\">End Point Mobile 2<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint8<\/td><td class=\"column-7\">2 car<\/td>\n<\/tr>\n<tr class=\"row-69\">\n\t<td class=\"column-1\">DPM3<\/td><td class=\"column-2\">Start Point Mobile 3<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint8<\/td><td class=\"column-7\">2 car<\/td>\n<\/tr>\n<tr class=\"row-70\">\n\t<td class=\"column-1\">FPM3<\/td><td class=\"column-2\">End Point Mobile 3<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint8<\/td><td class=\"column-7\">2 car<\/td>\n<\/tr>\n<tr class=\"row-71\">\n\t<td class=\"column-1\">RELAIS<\/td><td class=\"column-2\">RELAIS<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint16<\/td><td class=\"column-7\">3 cars<\/td>\n<\/tr>\n<tr class=\"row-72\">\n\t<td class=\"column-1\">NJOURF<\/td><td class=\"column-2\">Number of current day supplier calendar<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint8<\/td><td class=\"column-7\">2 car<\/td>\n<\/tr>\n<tr class=\"row-73\">\n\t<td class=\"column-1\">NJOURF+1<\/td><td class=\"column-2\">Number of the next supplier calendar day<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint8<\/td><td class=\"column-7\">2 car<\/td>\n<\/tr>\n<tr class=\"row-74\">\n\t<td class=\"column-1\">PJOURF+1<\/td><td class=\"column-2\">Profile of the next supplier calendar day<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">String<\/td><td class=\"column-7\">98 car<\/td>\n<\/tr>\n<tr class=\"row-75\">\n\t<td class=\"column-1\">POINT 1<\/td><td class=\"column-2\">Profile of the next peak day<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">String<\/td><td class=\"column-7\">98 car<\/td>\n<\/tr>\n<tr class=\"row-76\">\n\t<td class=\"column-1\">&#8211;<\/td><td class=\"column-2\">Linky protocol<\/td><td class=\"column-3\">&#8211;<\/td><td class=\"column-4\">0<\/td><td class=\"column-5\"><\/td><td class=\"column-6\">Uint8<\/td><td class=\"column-7\">1 car<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\r\n\r\n\r\n<h2><span class=\"ez-toc-section\" id=\"Donnees_Home_Assistant_sur_mode_Standard\"><\/span>Data Home Assistant on Standard Mode<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>And that's it, all the data is present in Home Assistant (the same can obviously be consulted on Zigbee2MQTT)<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8084\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky17.png\" alt=\"\" width=\"721\" height=\"858\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky17.png 721w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky17-600x714.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky17-252x300.png 252w\" sizes=\"auto, (max-width: 721px) 100vw, 721px\" \/><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8085\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky18.png\" alt=\"\" width=\"687\" height=\"482\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky18.png 687w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky18-600x421.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky18-300x210.png 300w\" sizes=\"auto, (max-width: 687px) 100vw, 687px\" \/><\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Tentative_de_comprehension_des_changements_detats_HCHP\"><\/span>Attempt to understand changes in HC\/HP states<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>So now it\u2019s an adventure, I don\u2019t really understand what\u2019s going on.<\/p>\r\n<p>My HC\/HP time changes are for example on 14:06 and 17:06 and here is the history recorded today:<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8090\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/736f22e3b4987ec4ed8cba91edff5d2f7f1c30e4.png\" alt=\"\" width=\"343\" height=\"400\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/736f22e3b4987ec4ed8cba91edff5d2f7f1c30e4.png 343w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/736f22e3b4987ec4ed8cba91edff5d2f7f1c30e4-257x300.png 257w\" sizes=\"auto, (max-width: 343px) 100vw, 343px\" \/><\/p>\r\n<p>Pretty incomprehensible then.<\/p>\r\n<p>I wait one night to see the physical switch (heater console) and the indicators returned, here is the result:<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8103\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/5d97d5d99294237873ad9e3f80b1f9998b357179_2_690x236.png\" alt=\"\" width=\"690\" height=\"236\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/5d97d5d99294237873ad9e3f80b1f9998b357179_2_690x236.png 690w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/5d97d5d99294237873ad9e3f80b1f9998b357179_2_690x236-600x205.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/5d97d5d99294237873ad9e3f80b1f9998b357179_2_690x236-300x103.png 300w\" sizes=\"auto, (max-width: 690px) 100vw, 690px\" \/><\/p>\r\n<p>I therefore note that:<\/p>\r\n<ul>\r\n<li>STGE and conso correspond and are on the right time 02:06:07 for both.<\/li>\r\n<li>02:14:07 for NTARF and RELAIS.<\/li>\r\n<\/ul>\r\n<p>At this stage, I do not explain the reason for the discrepancy, I will question on the forums to see if anyone knows, but at this stage, I will therefore use STGE to define whether we are in HC or HP.<\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Jajoute_un_Template_pour_avoir_HCHP\"><\/span>I add a template to have HC\/HP<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>In my templates.yaml file, I add:<\/p>\r\n<pre class=\"EnlighterJSRAW\" data-enlighter-language=\"yaml\">- name: Single current _id tariff period: sensor.period _tarifaire _en _cours state: &gt;- {% if is_state(\"sensor.linky_status _register\", \"003AC401\") %} HP {% else %} HC {% endif %}<\/pre>\r\n<h2><span class=\"ez-toc-section\" id=\"Comprendre_les_5_lignes_Energie\"><\/span>Understanding the 5 Energy Lines<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8093\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky19.png\" alt=\"\" width=\"312\" height=\"202\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky19.png 312w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky19-300x194.png 300w\" sizes=\"auto, (max-width: 312px) 100vw, 312px\" \/><\/p>\r\n<p>I find myself in HA with 5 lines with the same title.<\/p>\r\n<p>They correspond to the lines:<\/p>\r\n<ul>\r\n<li>EAST<\/li>\r\n<li>EASTF01<\/li>\r\n<li>EASTF02<\/li>\r\n<li>EASD01<\/li>\r\n<li>EASD02<\/li>\r\n<\/ul>\r\n<p>I went to check the indexes on the meter display to find myself there.<\/p>\r\n<p>I give up EASD01 and EASD02, I don\u2019t understand High Season, Low Season.<\/p>\r\n<p>EAST is therefore the total consumption, EASTF01 the Conso Heures Creuses, EASTF02 the Conso H Pleines.<\/p>\r\n<p>That is immediately clearer:<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8095\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky19-2.png\" alt=\"\" width=\"315\" height=\"132\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky19-2.png 315w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky19-2-300x126.png 300w\" sizes=\"auto, (max-width: 315px) 100vw, 315px\" \/><\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Jajoute_les_informations_de_conso_dans_Energy\"><\/span>I add conso information in Energy<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8096\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky20.png\" alt=\"\" width=\"418\" height=\"621\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky20.png 418w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky20-202x300.png 202w\" sizes=\"auto, (max-width: 418px) 100vw, 418px\" \/><\/p>\r\n<p>and<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8097\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky21.png\" alt=\"\" width=\"412\" height=\"395\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky21.png 412w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky21-300x288.png 300w\" sizes=\"auto, (max-width: 412px) 100vw, 412px\" \/><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8100\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky22.png\" alt=\"\" width=\"381\" height=\"378\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky22.png 381w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky22-100x100.png 100w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky22-300x298.png 300w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky22-150x150.png 150w\" sizes=\"auto, (max-width: 381px) 100vw, 381px\" \/><\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Donnees_que_je_conserve_finalement\"><\/span>Data that I finally keep<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>After a battery of tests, I confirm what I thought, the real-time information is worthless, the Linky is not made for it. No need to think of having the instant conso thanks to him.<\/p>\r\n<p>I therefore use it to retrieve the HC\/HP info and to power HA\u2019s Energy module.<\/p>\r\n<p>Here are the data I keep:<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8118\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky23.png\" alt=\"\" width=\"333\" height=\"465\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky23.png 333w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky23-215x300.png 215w\" sizes=\"auto, (max-width: 333px) 100vw, 333px\" \/><\/p>\r\n<p>MSG1 and MSG2, I keep them because I'm curious about what might happen in these message fields. We will see in several months or years if something appears.<\/p>\r\n<p>NTARF\/RELAIS\/STGE, I will wait several days to see which of the 3 I keep, I will disable the other two then.<\/p>\r\n<p>I keep the Conso Totale at this stage, but if I do not need it, I will deactivate it.<\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Precision_de_la_configuration_du_module_dans_Zigbee2MQTT\"><\/span>Accuracy of module configuration in Zigbee2MQTT<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8119\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky24.png\" alt=\"\" width=\"973\" height=\"612\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky24.png 973w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky24-600x377.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky24-300x189.png 300w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky24-768x483.png 768w\" sizes=\"auto, (max-width: 973px) 100vw, 973px\" \/><\/p>\r\n<p>In the whitelist, it seems important to specify the information you need, it seems to limit the resources to send unnecessary data. I specified \u201cEAST,EAIT,EASF01,EASF02,STGE,NTARF,RELAIS,MSG1,MSG2\u201d<\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>Finally, the fairly simple and efficient integration of this module allows me to feed the Energy module of Home Assistant and to have the information of HC\/HP on my Dashboard.<\/p>\r\n<p>This RetEx is still to be completed in time, it will evolve, I have left a few outstanding points above.<\/p>\r\n<p>The readings of the various forums or Retex of other users suggest to me that the realisation of this type of equipment is particularly complex to achieve. Obviously the power supply provided to the module by the Linky is very very low, so it must be extremely optimised. The choice of Zigbee is a good thing, it is a technology that consumes very little, I imagine that in Wifi or Bluetooth, it would not work.<\/p>\r\n<p>Being able to choose a whitelist of the data you want to use has to lighten the frames and the energy requirement of the module, which is a great idea.<\/p>\r\n<p>Congratulations for the realization of this module, a very good job!<\/p>\r\n<p>As a bonus, here is the Energy screen on my Dashboard, if that gives any ideas.<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8122\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky25.png\" alt=\"\" width=\"1725\" height=\"852\" srcset=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky25.png 1725w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky25-600x296.png 600w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky25-300x148.png 300w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky25-1024x506.png 1024w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky25-768x379.png 768w, https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/11\/linky25-1536x759.png 1536w\" sizes=\"auto, (max-width: 1725px) 100vw, 1725px\" \/><\/p>\r\n<p><a href=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/02\/tests.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-6286\" src=\"https:\/\/www.sigalou-domotique.fr\/wp-content\/uploads\/2024\/02\/tests.png\" alt=\"\" width=\"100\" height=\"121\" \/><\/a><\/p>\r\n<p>&nbsp;<\/p>\r\n<h2><span class=\"ez-toc-section\" id=\"Bibliographie_ou_references\"><\/span>Bibliography or references<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<ul>\r\n<li class=\"entry-title\"><a href=\"https:\/\/faire-ca-soi-meme.fr\/domotique\/2024\/10\/14\/les-bonnes-pratiques-de-la-teleinformation-tic-linky\/\" target=\"_blank\" rel=\"noopener\">ICT teleinformation best practices \u2013 Linky 14 October 2024<\/a><\/li>\r\n<li><a href=\"https:\/\/www.enedis.fr\/media\/2035\/download\" target=\"_blank\" rel=\"noopener\">https:\/\/www.enedis.fr\/media\/2035\/download<\/a><\/li>\r\n<li><a href=\"https:\/\/github.com\/fairecasoimeme\/Zlinky_TIC\" target=\"_blank\" rel=\"noopener\">https:\/\/github.com\/fairecasoimeme\/Zlinky_TIC<\/a><\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\r\n\r\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Where to buy this equipment? Here is the link to his page dedicated to ZlinkyTIC. I referenced the sellers and prices.<\/p>","protected":false},"author":1,"featured_media":7971,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[14,53,108,68],"tags":[],"class_list":["post-7970","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-domotique","category-home-assistant","category-test-produit","category-zigbee-materiels"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.sigalou-domotique.fr\/en\/wp-json\/wp\/v2\/posts\/7970","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sigalou-domotique.fr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sigalou-domotique.fr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sigalou-domotique.fr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sigalou-domotique.fr\/en\/wp-json\/wp\/v2\/comments?post=7970"}],"version-history":[{"count":0,"href":"https:\/\/www.sigalou-domotique.fr\/en\/wp-json\/wp\/v2\/posts\/7970\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sigalou-domotique.fr\/en\/wp-json\/wp\/v2\/media\/7971"}],"wp:attachment":[{"href":"https:\/\/www.sigalou-domotique.fr\/en\/wp-json\/wp\/v2\/media?parent=7970"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sigalou-domotique.fr\/en\/wp-json\/wp\/v2\/categories?post=7970"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sigalou-domotique.fr\/en\/wp-json\/wp\/v2\/tags?post=7970"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}